Sefam S.Box Heated CPAP Humidifier
−10%at checkout · BLACKFRIDAY10
Black Friday · ends Monday 30 November, 23:59
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
−10%at checkout · BLACKFRIDAY10
Black Friday · ends Monday 30 November, 23:59
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
VAT relief applied — no VAT will be charged at checkout.
Souvent achetés ensemble
Ajoutez l'ensemble en une fois.
SEFAM S.Box CPAP Unit
£299.99
- Marque
- Sefam
- catégorie
- CPAP Humidification
- Réf.
- SEF4202V
- Options
- 2 au choix
Sefam S.Box Heated CPAP Humidifier with Water Chamber, New
The Sefam heated humidifier is the docking humidifier built for the S.Box auto CPAP, supplied as a heater plate and a 350 mL water chamber that together replace the side cover of the machine. Humidification runs across ten levels from the touch screen, delivering more than 12 mg of water per litre of air at the top setting, and the combined machine and humidifier measure 245 by 185 by 110 mm and weigh 1.7 kg.
Humidification is what makes CPAP tolerable for most people who struggle with it. Air driven through the nose all night at pressure dries the mucosa, and a dry nose blocks, bleeds and wakes people up, which is how a machine ends up in a cupboard. Warming and wetting the air on its way out of the device deals with that at source. Sefam set the output on a scale of one to ten rather than as a single on and off, so the level can be dialled to the season and the bedroom rather than left at whatever the factory chose.
The two named functions on this humidifier both address the same nuisance, which is condensation. Humid Control plus manages the output so humidified air does not cool and drop its water in the tube, and Adaptive Thermo Control, used with Sefam's optional heated tube, ties the tube's heating to the humidifier setting so the air arrives at the mask at the temperature it left at. Without a heated tube the air cools on the way and the water collects in the hose and gurgles, which is the commonest complaint about any humidified CPAP setup. Sefam cap the gas temperature reaching the patient at 43 degrees Celsius.
It docks by hand and without tools. The side cover comes off the machine at the unlock button, the heater plate slides onto the side rails and locks with a latch, and the chamber base clips onto the plate. The chamber lifts out for filling away from the machine, takes distilled water at room temperature, and goes in a dishwasher at up to 70 degrees Celsius for its weekly clean, which is more than most water chambers will tolerate.
References
| Brand | Sefam |
| Product | Heated humidifier with water chamber |
| Fits | Sefam S.Box auto CPAP |
| Usable water volume | 350 mL |
| Humidification levels | Off, then 1 to 10 |
| Humidification output | More than 12 mg of water per litre at maximum |
| Named functions | Humid Control plus, and Adaptive Thermo Control with the heated tube |
| Sefam reference, heated humidifier | M-216430-06 |
| Sefam reference, water chamber | M-216430-15 |
| Place of manufacture | France |
| Condition | New |
Features
- Docks to the S.Box in place of the side cover, by hand and without tools.
- Ten humidification levels set from the machine's touch screen.
- Output of more than 12 mg of water per litre of air at the top setting.
- 350 mL of usable water in the chamber.
- Humid Control plus, managing output so humidified air does not drop its water in the tube.
- Adaptive Thermo Control, tying the optional heated tube to the humidifier setting.
- Gas temperature to the patient capped at 43 degrees Celsius.
- Low resistance, at a pressure drop of 1.3 cm H2O at a flow of 1 litre per second.
- Chamber lifts out for filling away from the machine, with a maximum fill mark.
- Chamber parts take a dishwasher at up to 70 degrees Celsius.
- Combined machine and humidifier at 245 by 185 by 110 mm and 1.7 kg.
- Sound level with the humidifier fitted of 27.5 dBA.
- Built to EN ISO 8185 for respiratory humidifiers.
- Made in France.
Caractéristiques techniques
- Brand
- Sefam
- Condition
- New
- Product type
- Heated humidifier for a continuous positive airway pressure device
- Compatible device
- Sefam S.Box auto CPAP only
- Assembly
- Heater plate and water chamber, replacing the machine side cover
- Installation
- Heater plate slides onto side rails and latches, chamber base clips to the plate
- Usable water volume
- 350 mL
- Operational gas volume in the chamber
- 730 mL
- Humidification levels
- Off, then 1 to 10, set on the touch screen
- Humidification output
- More than 12 mg of water per litre at maximum, with leak below 60 litres per minute
- Heating time
- 45 minutes
- Maximum gas temperature delivered
- 43 degrees Celsius
- Pressure drop
- 1.3 cm H2O at a flow of 1 litre per second
- Maximum operating pressure
- 20 cm H2O
- Compliance, chamber empty
- 11 mL per kPa
- Compliance, chamber full
- 8 mL per kPa
- Heated tube settings, where the tube is fitted
- Off, 1 to 5, or Auto following the humidifier level
- Heated tube diameter
- 15 mm
- Device input
- 24 V direct current, plus or minus 20 per cent
- Maximum power draw
- 75 W, during mask disconnection
- Current at 20 cm H2O
- From 0.42 A, rising to 1.99 A with humidifier at 10 and heated tube at 5
- Power supply unit
- 100 to 240 V alternating current, 50 or 60 Hz
- Sound level with the humidifier fitted
- 27.5 dBA
- Dimensions, machine with humidifier
- 245 by 185 by 110 mm
- Weight, machine with humidifier
- 1.7 kg, without the power supply
- Water to use
- Distilled, at room temperature
- Not to be added
- Scented or aromatic oils, saline and other alkaline solutions
- Daily cleaning
- Rinse in clean water, air dry away from sunlight
- Weekly cleaning
- Warm water with a mild detergent, rinsed and dried, or a dishwasher cycle at up to 70 degrees Celsius
- Monthly cleaning
- Soak 15 minutes in one part white vinegar to nine parts water, rinse and dry
- Bleach
- Never above a 0.1 per cent solution
- Operating temperature with the humidifier
- Plus 5 to plus 35 degrees Celsius
- Storage and transport temperature
- Minus 25 to plus 70 degrees Celsius
- Altitude
- Around 0 to 2,500 m
- Transport
- Chamber emptied and heater plate removed before packing
- Standard for respiratory humidifiers
- EN ISO 8185
- Other standards for the system
- IEC 60601-1, IEC 60601-1-2 and ISO 80601-2-70
- Place of manufacture
- France
Les caractéristiques peuvent changer sans préavis. Demandez-nous le dossier technique à jour.
Contenu de la boîte
- Item
- Quantity
- Sefam heated humidifier heater plate
- 1
- Water chamber
- 1
Non inclus
- Item
- Status
- Sefam S.Box CPAP machine
- Not included
- Heated tube with Adaptive Thermo Control
- Not included, ordered separately
- Standard CPAP tubing
- Not included
- Power supply unit and mains lead
- Not included
- Spare water chamber
- Not included
- Distilled water
- Not included
- Mask and headgear
- Not included
- Carrying bag or case
- Not included
- Cleaning products
- Not included
Livraison
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
Douane et droits
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Retours
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
Lire la politique de retour complète
Cela n'affecte pas vos droits légaux.
Remboursement
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Commandé avec cet article
À ajouter à la même commande.
Autres articles de cette catégorie
Plus de produits dans la même catégorie.
Consultés récemment
Reprenez là où vous en étiez.
Poursuivez votre traitement avec des accessoires et pièces neufs